Pre-Donation Screening
| Hemoglobin | 14.8 g/dL |
| Blood Pressure | 122/78 |
| Pulse | 76 |
| Temperature | 36.7°C |
| Weight | 68 kg |
| Result | Pass |
| Screened By | Nasima Chowdhury |
Collection Details
| Donation Type | Whole Blood |
| Volume Collected | 450 mL |
| Bag Number | WB-450-889231 |
| Collected By | Nasima Chowdhury |
| Collection Date/Time | 2026-08-12 09:20 |
| Adverse Reaction | None |
TTI & Grouping Panel
| Test | Result | Flag |
| ABO / Rh Grouping |
O Positive |
Normal
|
| HIV 1/2 (Ag/Ab) |
Non-Reactive |
Normal
|
| HBsAg |
Non-Reactive |
Normal
|
| HCV Antibody |
Non-Reactive |
Normal
|
| Syphilis (VDRL/TPHA) |
Non-Reactive |
Normal
|
| Malaria Antigen |
Non-Reactive |
Normal
|
All TTI markers non-reactive. Unit cleared to proceed to component processing.
Component Separation
| Component | Volume | Unit ID | Storage Location | Expiry |
| Packed RBC |
280 mL |
BBU-26-01188 |
RBC Refrigerator — Shelf B2 |
2026-09-19 (42 days) |
| Fresh Frozen Plasma |
150 mL |
BBU-26-01189 |
Plasma Freezer — Rack F1 |
2027-08-12 (1 year) |
| Platelet Concentrate |
50 mL |
BBU-26-01190 |
Platelet Incubator — Bay P3 |
2026-08-17 (5 days) |
| Processed By | Kamal Hossain |
| Processing Date/Time | 2026-08-12 11:45 |
| Centrifugation Method | Heavy Spin — Standard Protocol |
Final Validation & Release
| TTI Screening | All Non-Reactive |
| Grouping Confirmed | O Positive |
| Visual Inspection | No Hemolysis/Clots |
| Component Labeling | Verified |